FANUC Alpha Servo Amplifier Alarm and Error Codes
The following alarm codes pertain to FANUC Alpha SVM series (part numbers started from A06B-6079, A06B-6080, A06B-6096, and A06B-6097). Knowing your error code could help us provide you with the fast and precise evaluation for repair or exchange services.
Please contact us for free consultation about any of the following error codes, or any other problems with your FANUC servo units. Call 630-616-0039 or fill up a contact form.
B-65162E (FANUC AC SERVO AMPLIFIER Description Manual) Fanuc I/O Manuals B-61813E Fanuc I/O Unit Model A Connection and Maintenance Manual. Fanuc CNC Controls. B-61813E/4 Fanuc I/O Unit Model A. B-65142EN/03 Fanuc Alpha Series Servo Motor Description Manual B-65262EN/06 Fanuc AC Servo Motor Ai Series Descriptions Manual. B-65162E (FANUC AC SERVO AMPLIFIER Description Manual) Fanuc I/O Manuals B-61813E Fanuc I/O Unit Model A Connection and Maintenance Manual. Fanuc CNC Controls. B-61813E/4 Fanuc I/O Unit Model A. B-65142EN/03 Fanuc Alpha Series Servo Motor Description Manual B-65262EN/06 Fanuc AC Servo Motor Ai Series Descriptions Manual. This manual describes the servo parameters of the CNC models using FANUC AC SERVO MOTOR αiS, αiF, and βiS series. The descriptions include the servo parameter start-up and adjustment procedures. The meaning of each parameter is also explained. Fanuc axis drive manual fanuc x axis velocity control unit manual.pdf a06b-6047 fanuc dc axis velocity control unit drives the fanuc dc m series axis controller drives come with single axis or twin axis and can drive from model 00m upto model 30m in standard configuarations. All dc axis drive services cnc offers come with a 180 day. The Fanuc Servo drive can be controlled by Type A or Type B interface this is selectable via switched on the servo drive amplifier, We have tested the Fanuc Servo Drive on a Fanuc OC test rig on a closed loop test using the correct specification of Fanuc Motor.
Alarm Code | Description of Alarm/Error |
---|---|
1 | Inverter: Internal cooling fan stopped |
2 | Inverter: Control power supply under voltage |
5 | Inverter: DC link under voltage |
6 | Inverter: Overheat |
8 | Inverter: DC link current alarm (L axis) |
8. | Inverter: IPM alarm (L axis) |
9 | Inverter: DC link current alarm (M axis) |
9. | Inverter: IPM alarm (M axis) |
Blinking | Inverter: abnormal control power supply |
A | Inverter: DC Link Current alarm (N axis) |
A. | Inverter: IPM alarm (N axis) |
b | Inverter: DC Inverter: Control Command Failure |
c | Inverter: DC Inverter: Control Command Failure |
d | Inverter: DC Inverter: Control Command Failure |
F | Inverter: cooling fan stopped of the radiator |
P | Inverter: Communication error between amplifier and module |
U | Inverter: FSSB communication error (COP10B) |
L | Inverter: FSSB communication error (COP10A) |
FANUC Servo Amplifier Series A06B-6089 and A06B-6090 Alarm Codes
The alarms and error code below are for FANUC Servo Amplifier Series A06B-6089 and A06B-6090. If an alarm condition occurs, the 7-segment LED indicator on the amplifier will behave according to the table below.
Alarm Code | Type |
---|---|
1 | Over Voltage alarm (HV) |
2 | Low control power voltage alarm (LV) |
3 | Low DC link voltage alarm (LVDC) |
4 | Regenerative discharge control circuit failure alarm (DCSW) |
5 | Over regenerative discharge alarm (DCOH) |
7 | Dynamic brake circuit failure alarm (DBRLY) |
8 | L-axis over current alarm (HCL) |
9 | M-axis over current alarm (HCM) |
6 | L and M axis over current alarm (HCM) |
8 | L-axis IPM alarm (IPML) |
9 | M-axis IPM alarm (IPMM) |
b | L and M axis IPM alarm |
Trips | Circuit breaker |
FANUC A06B-6114, A06B-6117 Series Alarms and Error Codes
The alarms and error codes below are FANUC Alpha I Servo Amplifier Module Alarms covering the series of FANUC A06B-6114, A06B-6117 Alpha servo amplifiers.
Alarm Code | Description of Alarm/Error |
---|---|
1 | Inverter: Internal cooling fan stopped |
2 | Inverter: Control power supply under voltage |
5 | Inverter: DC link under voltage |
6 | Inverter: Overheat |
F | Inverter: cooling fan stopped of the radiator |
P | Inverter: Communication error between amplifier and module |
8 | Inverter: DC link current alarm |
8.9.A | Inverter: IPM alarm |
8.9.A | Inverter: IPM alarm (OH) |
bcd | Inverter: IPM alarm (OH) |
Request a Free Consultation
Please contact us for free consultation about any of the following error codes, or any other problems with your FANUC servo amplifier. Call 630-616-0039 or fill up a contact form.
Our Repair Services
MRO Electric repairs CNCs, PLCs, Servo/Spindle Drives, Motors, Amplifiers, VFDs, HMIs, and more, most of which can be repaired in only 3-5 days.
Repair Benefits
MRO can restore your failed A06B-6089-H105 to remanufactured condition and save you up to 75% compared to buying new. We offer standard repair pricing to ensure you the best value for your repair.
Our certified technicians use rigorous testing procedures to ensure your parts are restored to fully functioning condition. Our team proudly stands behind all repairs by providing a minimum 2 year warranty.
Our technicians have vast experience with most manufacturers and models. In addition to this A06B-6089-H105 we also repair drives, motors, PLCs and more, so if you don’t see the model you need, please contact us.
Core Exchange
Fanuc Axis Drive Manual Download
If you are interested in getting credit for your faulty A06B-6089-H105, just let us know and we can issue you an RMA to send it in as an exchange. Our exchange program provides you with savings and keeps us stocked for the next time you need anything.